INDUSTRIES SERVED

For manufacturers who need better service from their testing laboratory, we are a non-profit compliance testing lab making complex straightforward. Unlike a run-of-the-mill testing lab, we were founded by manufacturers, for manufacturers. We work for, and with our members.

For more information on the industries in which we serve, please view the industry in which you are most interested.

Here is a list of commonly requested methodologies in which we routinely perform for your industry. We also welcome customer specific protocols as well as custom requirements.

Representative Products Include:

Ruggedized Rackmount Computers
Wireless Ethernet Radios
Solid-state Enterprise Storage
Blue-tooth Devices
RFID
Enterprise Dervers
Monitors, Displays, Signage
Ethernet Switches

EN 55011 or CISPR11 Industrial, scientific and medical equipment – RF disturbance characteristics – Limits and methods of measurement
EN 55022 or CISPR22 Information technology equipment – RF disturbance characteristic – Limits and methods of measurement
IEC / EN 61000 -3-2 (EMC) – Limits – Limits for harmonic current emissions
IEC / EN 61000 -3-3 (EMC) – Limits – Limitation of voltage changes, voltage fluctuations and flicker
IEC / EN 61000 -4-11 (EMC) – Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
IEC / EN 61000 -4-2 (EMC) – Testing and measurement techniques – Electrostatic discharge immunity test
IEC / EN 61000 -4-3 (EMC) – Testing and measurement techniques – Radiated , radio-frequency, electromagnetic field immunity test
IEC / EN 61000 -4-4 (EMC) – Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC / EN 61000 -4-5 (EMC) – Testing and measurement techniques – Surge immunity test
IEC / EN 61326 -1 Electrical equipment for measurement, control and laboratory use. EMC requirements. General requirements
IEC / EN 60601 -1-2 Medical electrical equipment – General requirements for basic safety and essential performance – Collateral standard: Electromagnetic compatibility – Requirements and tests
FCC Part 15 Radio Frequency Devices
FCC Part 18 Industrial Scientific and Medical Devices
MIL-STD 167 -1A Typ 1 Mechanical vibration of shipboard equipment (Type 1 – Environmental)
MIL-STD 810G M 500.5 Low Pressure (Altitude)
MIL-STD 810G M 501.5 High Temperature
MIL-STD 810G M 502.5 Low Temperature
MIL-STD 810G M 514.6 Vibration
MIL-STD 810G M 516.6 Shock

Download Brochure

Here is a list of commonly requested methodologies in which we routinely perform for your industry. We also welcome customer specific protocols as well as custom requirements.

Representative Products Include:

Benchtop Autosamplers
Field Portable Analyzers
Process and Lab Analyzers
Benchtop Circulators, Baths, Heaters, Chillers
Field Deployable Autosamplers
Metrology Equipment
Analytical Sensors and Probes
Automated Sample Prep

EN 55011 or CISPR11 Industrial, scientific and medical equipment – RF disturbance characteristics – Limits and methods of measurement
IEC / EN 60601 -1-2 Medical electrical equipment – General requirements for basic safety and essential performance – Collateral standard: Electromagnetic compatibility – Requirements and tests
IEC / EN 61000 -3-2 (EMC) – Limits – Limits for harmonic current emissions
IEC / EN 61000 -3-3 (EMC) – Limits – Limitation of voltage changes, voltage fluctuations and flicker
IEC / EN 61000 -4-2 (EMC) – Testing and measurement techniques – Electrostatic discharge immunity test
IEC / EN 61000 -4-3 (EMC) – Testing and measurement techniques – Radiated , radio-frequency, electromagnetic field immunity test
IEC / EN 61000 -4-4 (EMC) – Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC / EN 61000 -4-5 (EMC) – Testing and measurement techniques – Surge immunity test
IEC / EN 61000 -4-11 (EMC) – Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
IEC / EN 61000 -6-1 (EMC) – Generic standards – Immunity for residential, commercial and light-industrial environments
IEC / EN 61000 -6-3 (EMC) – Generic standards – Emission standard for residential, commercial and light-industrial environments
IEC / EN 61010 -1 Safety Requirements for electrical equipment for measurement, control, and laboratory use
IEC / EN 61010 -2-010 Particular requirements for laboratory equipment for the heating of materials
IEC / EN 61010 -2-051 Particular requirements for laboratory equipment for mixing and stirring
IEC / EN 61010 -2-081 Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes
IEC / EN 61326 -1 Electrical equipment for measurement, control and laboratory use. EMC requirements. General requirements
FCC Part 15 Radio Frequency Devices
FCC Part 18 Industrial Scientific and Medical Devices

Download Brochure

Here is a list of commonly requested methodologies in which we routinely perform for your industry. We also welcome customer specific protocols as well as custom requirements.

Representative Products Include:

Irrigation Control Panels
Storage and Conveying Electronics
GPS Systems for Precision Agriculture
Fluid Handling Systems
GIS Systems for Precision Agriculture
Truck Transport Electronic Accessories
Rail Transport Electronic Accessories
Bulk Material Handling Controllers and Sensors

EN ISO 10605 Road vehicles — Test methods for electrical disturbances from electrostatic discharge
EN ISO 11452 -5 Road vehicles — Component test methods for electrical disturbances from narrowband radiated EM energy
EN ISO 14982 Agricultural and forestry machinery — — Test methods and acceptance criteria
EN 55011 or CISPR11 Industrial, scientific and medical equipment – RF disturbance characteristics – Limits and methods of measurement
EN 55022 or CISPR22 Information technology equipment – RF disturbance characteristic – Limits and methods of measurement
IEC / EN 60335 -1 Safety of household and similar electrical appliances
IEC / EN 61000 -3-2 (EMC) – Limits – Limits for harmonic current emissions
IEC / EN 61000 -3-3 (EMC) – Limits – Limitation of voltage changes, voltage fluctuations and flicker
IEC / EN 61000 -4-2 (EMC) – Testing and measurement techniques – Electrostatic discharge immunity test
IEC / EN 61000 -4-3 (EMC) – Testing and measurement techniques – Radiated , radio-frequency, electromagnetic field immunity test
IEC / EN 61000 -4-4 (EMC) – Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC / EN 61000 -4-5 (EMC) – Testing and measurement techniques – Surge immunity test
IEC / EN 61000 -6-3 (EMC) – Generic standards – Emission standard for residential, commercial and light-industrial environments
IEC / EN 61000 -6-4 (EMC) – Generic standards – Emission standard for industrial environments
IEC / EN 61010 -1 Safety Requirements for electrical equipment for measurement, control, and laboratory use
MIL-STD 810G M 509.5 Salt Fog

Here is a list of commonly requested methodologies in which we routinely perform for your industry. We also welcome customer specific protocols as well as custom requirements.

Representative Products Include:

Industrial Controls/Sensors
High Voltage Power Supplies
Power Distribution
Lighting
Signs and Displays
Batteries and Chargers
Electrical and Lighting Connectors
Energy and Power Controls/Sensors
Flow and Level Control

EN 55011 or CISPR11 Industrial, scientific and medical equipment – RF disturbance characteristics – Limits and methods of measurement
EN 55022 or CISPR22 Information technology equipment – RF disturbance characteristic – Limits and methods of measurement
ANSI/IEC 60529 Degrees of Protection Provided by Enclosures (IP Code)
IEC / EN 61000 -3-2 (EMC) – Limits – Limits for harmonic current emissions
IEC / EN 61000 -3-3 (EMC) – Limits – Limitation of voltage changes, voltage fluctuations and flicker
IEC / EN 61000 -4-2 (EMC) – Testing and measurement techniques – Electrostatic discharge immunity test
IEC / EN 61000 -4-3 (EMC) – Testing and measurement techniques – Radiated , radio-frequency, electromagnetic field immunity test
IEC / EN 61000 -4-4 (EMC) – Testing and measurement techniques – Electrical fast transient/burst immunity test
IEC / EN 61000 -4-5 (EMC) – Testing and measurement techniques – Surge immunity test
IEC / EN 61000 -4-8 (EMC) – Testing and measurement techniques – Power frequency magnetic field immunity test
IEC / EN 61000 -6-2 (EMC) – Generic standards – Immunity for industrial environments
IEC / EN 61000 -6-4 (EMC) – Generic standards – Emission standard for industrial environments
IEC / EN 61326 -1 Electrical equipment for measurement, control and laboratory use. EMC requirements. General requirements
FCC Part 15 Radio Frequency Devices
FCC Part 18 Industrial Scientific and Medical Devices

Don’t see your industry listed? CONTACT US to see how we might be able to serve you.